FINNCOLD THAWING ROOM MTS-24

Product number 1101012024


Easy modular solution

Kometos Finnmodules modular facilities are standardised and they allow customers to easily expand their plant at a later stage when their needs and production grow. Kometos offers a wide range of solutions from one module entry level solutions (Thomcont) to facilities consisting of up to 30 modules.

Technical information

Size 7400 x 4400 x 3100 (4500)
Capacity 24 euro pallets (14 400 kg) / process
Range

-20 °C (-18 °C) … +2 °C,
Products in E2-boxes or trolleys. If the products are in boxes, thawing spacers must be inserted between the layers.

Optimal thawing process is achieved when the product´s start temperature is -20 °C (-18 °C) for both the scheduled process and the so called direct thawing process.

Defrosting time Varies by product / by packaging, indicative times:
-20 °C…- 2 °C            8 - 12 h
-20 °C…+ 2 °C         12 - 18 h 
Cooling Cooling by means of a cooling agent. A coolant available in the system of the plant, such as NH3, glycol, freezium or similar. The solution is pumped to the heat exchanger delivered by Kometos. The machinery contains 2 cooling blocks. Cooling capacity requirement: 25 kW. Max. temperature of the solution: -15 °C. 
Delivery limit The client shall supply and connect a pipeline from their own cooling system to the valves delivered by Kometos. Kometos shall deliver the required valves, heat exchangers, pumps and pipelines from the heat exchanger to the room.
Heating Heating by means of a heating agent. A heated solution available in the system of the plant, such as glycol, freezium or similar. Heating capacity need: 90 kW. Minimum temperature of the solution: +40 °C.
Delivery limit The client shall supply and connect a pipeline from their own cooling / heating system to the valves delivered by Kometos. The client shall provide for a possible supplementary filling of the system, if required.
Air circulation Air circulation with EC-fans
Intermediate level / Air guide Electromechanical spindle motors for lifting and lowering the intermediate level.
PLC control Control PLC KOMETOS. The operating panel is located outside the room next to the door.  Thawing equipment can be connected to the client’s Ethernet data network through which  Kometos has the opportunity for a secure service connection.
INTERFACE DATA
Electrical connection 400 V 63 A/room
Water connection R ½”, 4 bar
Compressed air supply R ½”, 2,8 bar
Drain connection Ø 48 mm